Q4 (16 Marks) Boilers & Steam 🔥 Repeated 9x in exams
MEKG • Written Exam

You were asked to join a ship as a second engineer. During briefing, you were informed about frequent boiler uptake tires happening onboard. Prepare a plan for to reduce boiler uptake fires. How will you monitor the progress of your plan

and what instructions you will issue to the watch-keepers?

Appeared In: Feb 2021Dec 2019Sep 2019Mar 2019Feb 2019Jan 2019Oct 2018Sep 2018Apr 2018

Verified Model Answer (Text Solution)

Structured for DG Shipping MEO Class II examination scoring criteria.

Exam Ready
Plan to Reduce Boiler Uptake Fires:

Preventive Maintenance Schedule

  • Carry out regular cleaning, inspection, and adjustment to ensure optimal air-fuel ratio for complete combustion. This minimises the production of soot and unburnt carbon particles.
  • Ensure the fuel oil fed to the boiler is properly treated to minimise impurities that contribute to incomplete combustion.
  • Conduct frequent inspections to identify and address any issues like burner misalignment, damaged refractory, or excessive soot accumulation before they escalate into a fire.
  • Whenever a flame failure occurs, immediately investigate and rectify the root cause to prevent prolonged incomplete combustion. Do not attempt repeated re-ignition until the cause is identified and resolved.

Soot Removal:
  • Implement a more frequent soot-blowing schedule: Develop a revised soot-blowing schedule that is more frequent than the current practice, balancing the need for soot removal with the risk of accelerating a small fire. The schedule should be based on soot accumulation monitoring, possibly through visual inspection or automated monitoring systems. (This is an important addition because merely avoiding soot blowers during a fire isn't enough – we must remove soot before fires start.)
  • Explore the feasibility of alternative soot removal methods such as water washing (potentially utilizing automated systems), to reduce the reliance on soot blowers.

Emergency Procedures (in case of fire): Fire in boiler uptake takes place in three stages:

(i) Normal Soot Fire:

  • Inform C/E and senior engineer
  • Start standby generator
  • Stop the main engine
  • Continue water circulating pump
  • Do not use soot blowers
  • Ensure exhaust valves are closed and cover turbocharger air filter
  • Start external boundary cooling
  • Use water dosing (for fire fighting) if fitted.

(ii) Hydrogen or Metal Fire:

  • Stop the main engine (if not already stopped)
  • Stop boiler water circulating pump
  • Shut all inlet/outlet valves in water circulating lines
  • Drain water from pipelines
  • Continue boundary cooling
  • If a fixed fire fighting system is fitted, activate it.
  • Monitor uptake temperature
  • After the fire is out, conduct thorough water washing
  • Inspect uptake for damage.


Monitoring and Watch Keeper Instructions:

Watchkeepers will be instructed to continuously monitor the following parameters and report any deviations immediately:

  1. Any significant rise indicates potential fire.
  2. Visible sparks or flames are clear indications of a fire.
  3. Activating high-temperature alarms necessitates immediate investigation.
  4. While not a direct indicator of fire, it may be a symptom of blocked flue gas pathways due to soot.
  5. Visual monitoring during routine inspections, aided by potentially installed soot accumulation sensors.