Situation: at sea in rough weather, fire sparks observed coming from the funnel; investigation shows the fuel contains considerable quantities of water and sludge. As Second Engineer:
- Notify the Chief Engineer and the bridge immediately, recording the time and the problem; if there is a risk of further escalation, prepare to reduce load.
- Stop/adjust the fuel flow to the engine and change over to a better-quality fuel (clean distillate or a different service tank) that is confirmed water/sludge-free, isolated the contaminated tank.
- Stop the purifiers gently/safely to prevent water entering the fuel system; change the fuel filters (or renew filter elements) - the pressure differential will have risen; the filter will be full of sludge/water.
- Bring in the standby/alternate service tank and Use the transfer lines to run on the good tank until the contamination is dealt with (purifiers refilled after draining).
- Drain any water collected at the bottom of the service tank drains; the sludge/water separator will have collected water - drain the automatic water drain and clean the filters.
- If the engine is running on badly contaminated HFO and the injectors/nozzles are blocked or the governor cannot hold speed, reduce engine speed/load to a safe minimum to prevent stalling.
- Take the contaminated fuel out of the system - put the contaminated tank(s) on a quarantine line, drain the water, and arrange to separate/transfer the good fuel; the purifier and its clarifier to be re-run only after the water/sludge is dealt with (usually after stopping and cleaning).
- Visually check the funnel/smoke and exhaust temperatures; if sparks persist or engine stalling occurs, stop the engine and have the injection/turbo cleaning and fuel system attended to; prepare standby arrangements.
The immediate aim is to prevent continued spraying of oil/sludge into the funnel (which ignites as sparks/soot) and to prevent engine damage.
- Institute proper fuel management: routine draining and cleaning of fuel oil tanks, correct purifier/centrifuge operation (set throughput and separation temperature correctly), and routine inspection and change of filter elements.
- Regular and correct purifier operation - maintain correct temperature, throughput and discard; carry out stand-by separators and keep the separator bowl clean; never operate with contaminated (watery/sludgy) tanks.
- Daily/weekly rounds: drain all fuel tanks' water drains regularly, check fuel oil service tanks for water, check filter differentials, and log. Ensure the automatic water drain/separator on the fuel line functions.
- Never allow water ingress: check for leaks in the steam tracing, fuel heaters, deck water, and any leaks between the fuel and water systems; ensure no contamination during bunkering - sample/top bunker quality, proper bunkering procedure.
- Prevent mixing fuel types: keep separate tanks for different fuels; never let water-contaminated or sludge-laden tanks be mixed into service, and keep correct settling to remove water.
- Maintain the fuel system clean: periodic cleaning of the fuel filters, heater, and lines; audit the on-board fuel specification and bunker analysis; check for oxidation/sludge build-up from ageing fuel.
- Dispose of sludge correctly (sludge tank), never return sludge to the fuel system.
- On the funnel side, good combustion by correct viscosity/temperature, and correct nozzle/atomization, maintaining proper scavenging so soot/oil does not ignite; keep the combustion and turbocharger clean.
The aim is to ensure only clean, dry, correctly filtered fuel reaches the engine so the stack remains clean and the risk of a funnel fire/engine damage is eliminated.