Q1 (16 Marks) Lubrication & Bearings 🔥 Repeated 5x in exams
MEP • Written Exam

Describe how the following conditions are prevented in auxiliary boilers:

(a) Feed contamination by oil from heating coil drains;

(b) Internal corrosion;

(c) Furnace blowback;

(d) Uptake fire.

Appeared In: Dec 2025Mar 2021Jan 2021Oct 2018Feb 2018

Verified Model Answer (Text Solution)

Structured for DG Shipping MEO Class II examination scoring criteria.

Exam Ready

(a) Feed Contamination by Oil from Heating Coil Drains

Prevention Measures:

  • Ensure heating coil drains are led to an observation tank or inspection glass before discharging overboard, so oil presence can be detected.
  • Provide and maintain steam traps and drain valves in good condition to avoid oil leakage into feed systems.
  • Fit non-return valves and isolating valves between heating coils and feedwater system.
  • Regularly inspect and test coil integrity to detect leaks early.
  • Avoid direct connection between heating coil drains and feedwater system without monitoring arrangements.

(b) Internal Corrosion

Prevention Measures:

  • Maintain correct boiler water treatment program to control pH and dissolved oxygen levels.
  • Use oxygen scavengers and chemical dosing as per manufacturer’s recommendations.
  • Maintain feedwater temperature in the cascade tank at about 85°C to aid oxygen release.
  • Keep feed tank and cascade tank lids/manholes closed to prevent air ingress.
  • Carry out regular blowdown to remove sludge and maintain proper alkalinity.
  • Inspect internal surfaces periodically and renew protective coatings if applied.

(c) Furnace Blowback

Prevention Measures:

  • Always carry out proper pre- and post-purging to clear combustible vapors from the furnace.
  • Maintain correct air–fuel ratio by ensuring proper functioning of air dampers, fuel regulators, and controllers.
  • Inspect and clean atomizers/burners to ensure fine fuel spray and complete combustion.
  • Check fuel viscosity and temperature to maintain correct atomization.
  • Avoid ignition attempts in a furnace containing unburnt fuel; purge thoroughly before re-lighting.
  • Ensure proper sequence and interlock functioning in the burner management system.

(d) Uptake Fire

Causes:

  • Accumulation of oily soot on tube surfaces due to incomplete combustion.
  • Poor circulation through tubes causing overheating.
  • High tube metal temperatures (>700°C).

Prevention Measures:

  • Carry out regular soot blowing and periodic washing of exhaust gas boilers to remove soot deposits.
  • Maintain proper air–fuel ratio and ensure complete combustion by checking damper and fuel control systems.
  • Ensure adequate steam and water flow in generating and superheater tubes to maintain good heat transfer and circulation.
  • Keep auxiliary blower running (manual mode if needed) to maintain airflow and prevent high exhaust temperatures during cut-off periods.
  • Maintain fuel oil injection viscosity between 12–13 cSt for correct atomization.
  • Incorporate extra soot-blowing routines when using fuels prone to high carbon deposition.