Write short notes on following: (16)
(a) Magnetic Particle Inspection (MPI)
(b) Ultrasonic Testing (UT)
(c) Radiographic Testing (RT)
(d) Liquid penetrant testing (PT)
Write short notes on following: (16)
(a) Magnetic Particle Inspection (MPI)
(b) Ultrasonic Testing (UT)
(c) Radiographic Testing (RT)
(d) Liquid penetrant testing (PT)
Structured for DG Shipping MEO Class II examination scoring criteria.
Used to detect surface and near-surface flaws in ferromagnetic materials (iron, steel, etc.). The material is magnetized, and finely divided ferromagnetic particles (iron powder) are applied to its surface. Flaws disrupt the magnetic field, causing the particles to accumulate at the defect locations, making them visible.
Employs high-frequency sound waves (ultrasonic) to detect internal and sometimes surface flaws. The ultrasonic waves are transmitted into the material, and any reflections caused by discontinuities are detected and measured. Methods include pulse-echo (single transducer sends and receives waves) and through-transmission (separate transducers transmit and receive).
A non-destructive testing method that uses penetrating radiation (X-rays or gamma rays) to detect internal flaws in materials. The radiation passes through the material, and variations in its intensity are recorded on a X-ray film. Darker areas on the image correspond to denser regions (defects) within the material. X-ray radiography is better suited for smaller defects, while gamma radiography can penetrate thicker materials and detect larger flaws.