OVERHAUL OF MAIN AIR COMPRESSOR VALVES (PLATE TYPE) AND TESTING
Procedure for overhauling the plate-type compressor valves
- Preparation: Stop the air compressor, isolate the air and cooling water, drain the intercooler/ aftercooler, and relieve the pressure. Obtain the maker's manual and the correct spares (valve plates, springs, seats, gaskets).
- Remove the valve assemblies: Remove the valve covers/ caps and withdraw the suction and discharge valve assemblies (the plate-type valves) from the cylinder head/ valve pockets. Mark each valve and its position.
- Dismantle the valve: Disassemble the valve - remove the valve plate(s), springs, and the valve seat/ guard. Note the arrangement and the number/ position of the springs.
- Clean all parts: Clean the valve plate, seat, springs and body using an appropriate solvent; remove carbon, oil and deposits. Do not damage the lapped/ sealing faces.
- Inspect each part:
- Valve plate: for wear, pitting, scoring, cracking, distortion and breakage; check the sealing face is flat and smooth.
- Valve seat: for wear, pitting, scoring and damage to the sealing face; check it is flat.
- Springs: for breakage, fatigue, loss of tension and corrosion; check the free length.
- Valve body/ guard: for cracks, wear and damage.
- Gaskets/ O-rings: for deterioration and damage.
- Renew as necessary: Replace worn/ damaged valve plates, springs, seats and gaskets with genuine spares. The valve plate and seat are often renewed together (matched).
- Reassemble the valve: Fit the new/ reconditioned parts in the correct order - the valve plate, springs and seat/ guard - ensuring the springs are correctly seated and the plate moves freely. Check the valve lifts correctly.
- Refit the valve assemblies: Fit the valve assemblies into the cylinder head/ valve pockets with new gaskets, and refit the covers/ caps, torquing to specification.
- Reconnect the air and cooling water, and test (see below).
Parts requiring close attention:
- The valve plate and seat sealing faces (must be flat, smooth and free of damage for a good seal).
- The springs (correct tension, no breakage).
- The valve plate lift/ travel (correct clearance).
- The gaskets/ O-rings (must be renewed to prevent leaks).
- The cleanliness of the valve pockets and the air passages.
Testing of the compressor valves
- Leak/ seat test: With the valve assembled, test the valve for leakage - the valve plate should seat and seal (no air/ liquid passing when the valve is closed). This can be done by applying air/ pressure to one side and checking for leakage, or by a leak test on the valve.
- Lift/ operation test: Check the valve plate lifts freely and returns to seat (no sticking).
- Compressor test: After refitting, run the compressor and check the interstage/ discharge pressures, the air delivery, and the valve operation (no abnormal noise, no overheating). Confirm the compressor reaches the correct pressure and delivers the rated capacity.
- Check for leaks: Check the valve covers/ gaskets for air leaks during the run.