The electric load may be increased slightly when the RPM will drop which may be restored by operating the control lever manually. Next, the electric load is reduced slightly when the RM will rise which again may be restored manually. If the operation is still erratic, the problem is with the engine. If the operation is normal then the problem is with the governor.
If the problem is with the engine, the following may be the causes:
- Fuel pump racks sticking
- Air lock in the fuel system
- Water in fuel
- Fuel pump plungers occasionally sticking
If the problem is with the governor, the erratic operation may be due to following causes:
- Actuator linkage sticking
- The Magnetic Pick Up unit (MPU) not adjusted properly, slack and moving thus the air gap varying
- Defective MPU
- Governor not adjusted properly; too high a gain may cause hunting; gain should be reduced in such case
- Loose electric connection
- Other problems in the electronic circuitry, PCB