Abnormal vibration has been observed in a HFO purifier while in operation. Explain the areas you plan to investigate for rectifying the faults and put back the purifier back to normal operations keeping in view that no reduction in vibration has been noticed even after desludging the purifier couple of times.

Appeared In: Sep 2019Apr 2019Jan 2019Jul 2019Jun 2019Mar 2019Sep 2018

Verified Model Answer (Text Solution)

Structured for DG Shipping MEO Class II examination scoring criteria.

Exam Ready

ABNORMAL VIBRATION IN AN HFO PURIFIER - INVESTIGATION AND RECTIFICATION

Since no reduction in vibration was noticed even after desludging the purifier a couple of times, the vibration is not due to accumulated sludge in the bowl. The areas to investigate:

  1. Bowl/ rotor balance: Check the bowl and the bowl components (disc stack, top disc, bowl hood) for balance. An out-of-balance bowl (from a damaged/ missing disc, an unevenly loaded bowl, or a bent bowl) causes vibration. Check the bowl is correctly assembled and the disc stack is even; check for a bent/ damaged bowl spindle.
  2. Bowl spindle/ shaft: Check the vertical shaft (bowl spindle) for bending, wear, and correct fit in the bearings. A bent or worn spindle causes vibration.
  3. Bearings: Check the bowl spindle bearings (the thrust/ radial bearings) for wear, pitting, damage and correct clearance. Worn/ damaged bearings cause vibration. Check the bearing lubrication (oil level, condition, pressure).
  4. Bowl drive/ coupling: Check the drive coupling (the friction/ centrifugal coupling, or the gear drive) for wear, damage and correct engagement. A worn/ slipping coupling causes vibration.
  5. Bowl locking/ assembly: Check the bowl is correctly locked/ assembled (the bowl hood, locking ring, and the bowl is correctly seated on the spindle). An incorrectly assembled/ loose bowl causes vibration.
  6. Motor/ drive: Check the drive motor and the motor bearings for wear/ damage; check the motor is correctly aligned with the purifier.
  7. Foundation/ mounting: Check the purifier's foundation, the anti-vibration mounts/ springs, and the securing bolts for damage, wear or looseness. A loose/ damaged foundation or mount causes vibration.
  8. Bowl internals: Check the bowl internals (discs, distributor, paring disc) for damage, blockage, or an unevenly loaded bowl (e.g. a broken disc).
  9. Balance/ run-out: Check the bowl run-out (dial indicator) and the overall balance; re-balance the bowl if necessary.

Rectification:

  • Correct the identified fault: re-balance/ re-assemble the bowl, renew the worn bearings/ spindle, repair the coupling, tighten/ repair the foundation/ mounts, or renew the damaged parts.
  • After rectification, run the purifier and check the vibration is within limits; confirm normal operation (correct separation, no abnormal noise/ vibration).