Q9 (16 Marks) Lubrication & Bearings
MEP • Written Exam

With reference to a water tube boiler:

(a) State the indication that a tube is leaking.

(i) When the amount of leakage is small.

(ii) When the amount of leakage is large.

(b) If the failed tube is located within the tube bank.

(i) How can it be identified.

(ii) Describe immediate actions and temporary repairs done.

Appeared In: Aug 2022

Verified Model Answer (Text Solution)

Structured for DG Shipping MEO Class II examination scoring criteria.

Exam Ready

TUBE LEAK IN A WATER TUBE BOILER

Part (a)

Indications that a tube is leaking

(i) When the amount of leakage is small:

  • A slight drop in boiler water level (increased feed water consumption).
  • A slight increase in the feed water flow/ make-up.
  • A hissing/ steam sound in the boiler (steam escaping into the gas side).
  • A slight increase in the boiler pressure/ temperature fluctuation.
  • Moisture/ steam at the boiler casing/ inspection openings.

(ii) When the amount of leakage is large:

  • A rapid drop in boiler water level (alarm/ low-level trip).
  • A large increase in feed water flow.
  • A loud steam/ water leak sound.
  • Steam/ water escaping from the boiler casing, flue or stack.
  • A drop in boiler pressure/ steam output.
  • Possible water hammer/ vibration.
  • A rise in the flue gas temperature (less heat absorbed) or a change in the gas analysis.
Part (b)

If the failed tube is located within the tube bank

(i) How it can be identified:

  • The leaking tube is identified by inspection (steam/ water marks, or by pressurising the water side and observing the leak location).
  • Within the tube bank, the leak is located by isolating sections/ by observing the steam/ water escaping from a specific tube, or by using a leak-detection method (e.g. pressurising and observing, or by the sound/ moisture at a specific tube).

(ii) Immediate actions and temporary repairs:

  • Isolate the boiler: shut off the fuel/ firing, shut off the steam and feed water, and allow the boiler to cool and depressurise.
  • Identify the leaking tube and plug it (temporary repair): fit a plug (tapered/ threaded or welded) at both ends of the tube (top and bottom) to isolate it, as per the maker/ Class-approved method.
  • Pressure test the boiler to confirm the plugged tube is leak-tight.
  • The boiler can then be returned to service (with the plugged tube) until a permanent repair (re-tubing) is carried out at the next opportunity.
  • Record the plugging and, where required, obtain surveyor/ Class approval.