(a) Describe the operating mechanism for a watertight door, which has provision for remote closure from the bridge and local operation.

(b) State the source of power for closure of electrical and the source of power for alarm and indicator

Appeared In: Jul 2022Oct 2021Jan 2018

Verified Model Answer (Text Solution)

Structured for DG Shipping MEO Class II examination scoring criteria.

Exam Ready
Part (a)

Operating Mechanism for a Watertight Door

In vessels with a large number of watertight bulkhead plates and access doors located below the waterline, a powered operating system is essential. Various systems are employed, primarily electrical and hydraulic types. A circuit diagram for a hydraulically operated system is commonly provided.

Hydraulic System Operation:

  • At each door, a motor-driven pump supplies oil at a pressure of 48 bar to a double-acting cylinder via a control valve.
  • This valve is actuated electrically by solenoids when operating from bridge control.

Local Control:

  • A local control station is positioned adjacent to each door, allowing for shut, open, or intermediate positions.
  • The manual control lever, operable from either side of the bulkhead, actuates a pilot valve that controls the pump motor circuit under all modes of control.
  • The system utilizes the area differential of the piston to provide a slightly greater force when opening the door.
  • The control lever is spring-loaded to the mid-position, ensuring a hydraulic lock within the cylinder. This prevents unintended movement of the door due to ship motion.

Bridge Control:

  • The bridge controller is designed to close up to 20 doors in sequence within 60 seconds.
  • This 60-second period includes a 10-second audible alarm at each door before closing begins. The alarm continues until the door is fully shut.
  • The “Close” and “Re-open” commands from the bridge energize the solenoids in the door’s control valve to activate the pump motor.
  • Limit switches, triggered by door movement, regulate the electrical circuit.
  • If any door is re-opened locally while under a "close" command from the bridge, it will automatically re-close when the local control lever is released.

Emergency Control:

  • In situations where no electrical power is available, the door can still be operated by manually using a hand pump and control valves at either the local or remote stations.

Light Indication System:

  • A colored light indicator on the bridge displays the status of each door:
    • Green – Door shut
    • Red – Door open
    Part (b)

    Source of Power for Closure, Alarm, and Indicator

    • The DC power supply for the pump is normally obtained from a DC/AC transformer rectifier unit, which is common to all doors in the system.
    • In emergency conditions, the power supply is sourced from the ship’s batteries.
    • To ensure continuous power availability, all indicator lights and audible alarms are connected to both the DC supply and the ship’s batteries.