What are the core features of the FSS Code? (International fire safety systems code).
Elaborate on any one test prescribed by the Code. (20)
What are the core features of the FSS Code? (International fire safety systems code).
Elaborate on any one test prescribed by the Code. (20)
Structured for DG Shipping MEO Class II examination scoring criteria.
Core features of the FSS Code (International Code for Fire Safety Systems).
The International Code for Fire Safety Systems (FSS Code) is a mandatory instrument under SOLAS Chapter II-2, laying down the international technical requirements for fire safety systems and equipment to be fitted on board ships. Its purpose is to provide uniform, design and test standards so that fixed and portable firefighting, fire detection and alarm systems comply with the performance requirements of SOLAS; the Administration/flag State may accept equivalent alternatives under the equivalency provision of SOLAS.
Elaboration of one test prescribed by the Code (example: test of fixed CO2 systems is complex, and the high-expansion foam, but a clear example is the "fire extinguishing medium supply" or the fire detection system? A good, clean one is the "test of the fixed foam or CO2 quantity" but an easier to describe one is the "fire detection" - the performance test of smoke/heat detectors):
Example test - smoke/heat detector and alarm system: The FSS Code (Chapter 9) requires that each fire detector and the fire alarm/warning system be tested. The detectors have to be of a type approved after being subjected to defined fire tests and response-temperature tests. Installation test: detectors must be arranged so the designed average spacing is such that smoke/heat from a fire in the protected space actuates at least one of the detectors and initiates the alarm. A test smoke (artificial smoke/glass of smoke) is applied and the panel must indicate the correct zone; the alarm must operate (audible and visual). The detector must be tested at installation and periodically, and the code requires a manual test facility and that the response be verified. Also the "testing of the fixed CO2" example: the system is pressure-tested to 1.5x working pressure, and the sealed discharge valves/operating controls tested by hydrostatic test of cylinders/pipework; the fire fighting medium (CO2 weight) is confirmed. I will describe the detection test as it gives a clean answer.