USCG USCG Steam
Set 12 • Question #101 of 496
Launch Interactive Practice Room In a cross-compounded turbine operating at full load, the total available steam energy is approximately divided between the HP and LP turbine in the ratio of __________.
A
1:1
✓ Correct Answer
B
2:1
C
3:1
D
4:1
USCG NMC Regulatory Explanation
In USCG Steam Plants (Boilers & Turbines), regarding 'In a cross-compounded turbine operating at full load, the total available steam energy is approximately divided between the HP and LP turbine in the ratio of', the verified engineering fact is: '1:1'.
Question Discussion & Notes
0Have a doubt, memory trick, or exam update? Share your insights with fellow mariners.
Loading mariner discussions...