USCG USCG Steam Set 13 • Question #137 of 496
Launch Interactive Practice Room

The turbo generator steam stop is located between the superheater outlet and the main steam stop valve to __________.

A
provide for easier access
B
provide higher quality steam for the turbo generators
C
provide a flow of cooling steam through the control desuperheater
D
allow the use of superheated steam in the turbo generator without pressurizing the larger main steam line ✓ Correct Answer