When raising vacuum on an auxiliary condenser, which of the following steps is necessary?

A
Close the makeup feed drag line to raise hotwell level.
B
Open the auxiliary condensate recirculation valve from the auxiliary air ejector condenser outlet. ✓ Correct Answer
C
Rotate turbine with hand jacking gear while applying gland seal steam.
D
Close condensate pump vent line to eliminate air leaks.