Launch Interactive Practice Room To allow for water drum expansion and contraction, most main propulsion boilers are fitted with __________.
A
U-bend tubes
B
expansion joints
C
sliding feet
✓ Correct Answer
D
spring supported pipe hangers
USCG NMC Regulatory Explanation
Main propulsion boilers are installed with sliding feet (slotted holding-down bolts) on one end of the water drum saddles to accommodate thermal expansion and contraction during heating and cooling, preventing structural damage to hull foundations.