When seated, the disc of a safety valve has an area of 0.75 square inches (1.9 sq cm). When the valve lifts the area is increased by 10%. If the valve lifts at 300 psig (2170 kPa), at approximately what pressure will the valve reseat?

A
262 psig (1907 kPa)
B
273 psig (1983 kPa) ✓ Correct Answer
C
284 psig (2059 kPa)
D
295 psig (2135 kPa)