USCG USCG Motor
Set 1 • Question #18 of 382
Launch Interactive Practice Room A large change in ambient temperature, or using an oil of a viscosity different than the one recommended by the manufacturer in a mechanical hydraulic governor, will result in the need to adjust the __________.
A
pilot valve opening
B
compensating needle valve
✓ Correct Answer
C
compensating spring tension
D
accumulator spring tension
USCG NMC Regulatory Explanation
Heavy Fuel Oil (HFO) must be preheated to achieve proper atomization viscosity (10-15 cSt) at the fuel injectors. Improper viscosity causes poor spray atomization, delayed ignition, and combustion chamber fouling.
Question Discussion & Notes
0Have a doubt, memory trick, or exam update? Share your insights with fellow mariners.
Loading mariner discussions...