Type a keyword to start searching...

Use ⌘K or Ctrl+K to search from anywhere
Benchmark: 70% Standard: USCG NMC / 46 CFR
USCG USCG Motor Set 12 • Question #116 of 382
Launch Interactive Practice Room

An 8000 horsepower diesel engine has a specific fuel consumption of 0.4 lbs. of fuel per horsepower hour. If each pound of fuel contains 18,500 BTU's and 25% of the available heat leaves the engine with the exhaust, how many BTU's per hour are theoretically available for use in a waste heat boiler?

A
7.4 million BTU's per hour
B
14.8 million BTU's per hour ✓ Correct Answer
C
22.2 million BTU's per hour
D
29.6 million BTU's per hour

Question Discussion & Notes

0

Have a doubt, memory trick, or exam update? Share your insights with fellow mariners.

Leave a Comment / Clarification

By posting, you agree to our Terms & Moderation Policy.

Loading mariner discussions...