The maximum allowable working pressure on a packaged auxiliary boiler is 200 psig. The normal working pressure for one particular packaged boiler is 175 psig. Which of the following safety relief valve settings would be proper for this boiler?

A
165 psig
B
195 psig ✓ Correct Answer
C
210 psig
D
220 psig