USCG USCG Motor Set 5 • Question #246 of 382
Launch Interactive Practice Room

If the flame of an automatically fired auxiliary boiler tends to move away from the burner tip when the firing rate is changed from low to high, you should __________.

A
decrease the fuel pressure
B
adjust damper linkage to slow the opening rate of the dampers ✓ Correct Answer
C
adjust damper linkage to lengthen the purge period
D
adjust the photocell to observe the new flame position