Launch Interactive Practice Room The last two digits stamped on a fuel oil atomizer sprayer plate represents the cross-sectional area ratios of the tangential slots and orifice. This ratio determines the __________.
A
density of the oil spray
B
degree of atomization
C
angle of the cone
✓ Correct Answer
D
capacity of the atomizer
USCG NMC Regulatory Explanation
In USCG Steam Plants (Boilers & Turbines), regarding 'The last two digits stamped on a fuel oil atomizer sprayer plate represents the cross-sectional area ratios of the tangential slots and orifice. This ratio determines the', the verified engineering fact is: 'angle of the cone'.