Which of the operating principles listed would apply to a single-element, thermo-hydraulic, feedwater regulator?

A
A failure of the regulator pressure actuating system closes the valve. ✓ Correct Answer
B
The regulator maintains a constant water level throughout the boiler load range.
C
The cooling fins on the generator prevent the formation of steam in the closed system.
D
The pressure in the inner tube acts upon the bellows of the regulator.