Fixed carbon dioxide extinguishing systems, for machinery spaces that are normally manned, are actuated by one control to open the stop valve in the line leading to the space, and:
Direct Answer
Option C: two separate controls to release the CO2
For normally manned machinery spaces protected by a CO2 system with a stop valve, a two-control operation is required. One control initiates the process (e.g., opening the stop valve), and a second control actually releases the CO2.
All Options
Detailed Explanation & Context
For normally manned machinery spaces protected by a CO2 system with a stop valve, a two-control operation is required. One control initiates the process (e.g., opening the stop valve), and a second control actually releases the CO2.
Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Advanced Fire Fighting (AFF).