RAFF Exit Exam • Set 1 Question 25 of 30

Which of the following statements does not apply to fire doors in main vertical zone bulkheads and stairway enclosures in passenger ships

✓

Direct Answer

Option B: If normally locked they do not have to be self-closing

Fire doors that are normally locked must still be self-closing to maintain compartment integrity. SOLAS Chapter II-2 mandates that fire doors in main vertical zones and stairway enclosures be self-closing and readily operable.

All Options

A
This shall be capable of being closed from control station unless they are normally closed
B
If normally locked they do not have to be self-closing (Correct Answer)
C
They shall be of the self closing type
D
They can have hold back hooks not subject to control station release providing the emergency plan details a person to close them

Detailed Explanation & Context

Fire doors that are normally locked must still be self-closing to maintain compartment integrity. SOLAS Chapter II-2 mandates that fire doors in main vertical zones and stairway enclosures be self-closing and readily operable.

Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Refresher Advanced Fire Fighting (RAFF).

Advertisement

Practice Full RAFF Set 1

Test yourself with 30 interactive questions, live timer, and instant score.

Launch Practice Simulator →

Question Discussion & Notes

0

Have a doubt, memory trick, or exam update? Share your insights with fellow mariners.

Leave a Comment / Clarification

By posting, you agree to our Terms & Moderation Policy.

Loading mariner discussions...