AIGF Exit Exam • Set 3 Question 12 of 30

In Direct connections of Flanged connections, For all piping except open ended, what restrictions is applied?

✓

Direct Answer

Option C: For design temperatures colder than minus 55°C, only welded neck flanges shall be used

For design temperatures colder than -55°C, only approved welding neck flanges with full penetration butt welds are permitted on fuel piping.

All Options

A
For design temperatures colder than minus 55°C, only welded slip on flanges shall be used
B
For design temperatures colder than minus 55°C, only welded threaded flanges shall be used
C
For design temperatures colder than minus 55°C, only welded neck flanges shall be used (Correct Answer)
D
For design temperatures colder than minus 55°C, only welded lap flanges shall be used

Detailed Explanation & Context

For design temperatures colder than -55°C, only approved welding neck flanges with full penetration butt welds are permitted on fuel piping.