AIGF Exit Exam • Set 9 Question 15 of 30
All pipelines isolated in a liquid full condition are provided with ___________
✓
Direct Answer
Option C: relief valves
Thermal relief valves must be installed on any pipeline section that can be isolated while full of liquid to prevent overpressurization from thermal expansion.
All Options
A
diaphgramvalves
B
butterfly valves
C
relief valves
(Correct Answer)
D
control valves
Detailed Explanation & Context
Thermal relief valves must be installed on any pipeline section that can be isolated while full of liquid to prevent overpressurization from thermal expansion.
Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Advanced Training for Ships subject to the IGF Code (AIGF).