Running two identical centrifugal cargo pumps in parallel will result in:
Direct Answer
Option B: Almost double the discharge flow rate with discharge pressure largely unchanged
Operating centrifugal pumps in parallel increases the total volumetric discharge flow rate (nearly double, depending on system backpressure) while the total discharge head/pressure remains approximately constant.
All Options
Detailed Explanation & Context
Operating centrifugal pumps in parallel increases the total volumetric discharge flow rate (nearly double, depending on system backpressure) while the total discharge head/pressure remains approximately constant.
Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Liquefied Gas Tanker Cargo Operations (LGTCO/LGTF).