Type a keyword to start searching...

Use ⌘K or Ctrl+K to search from anywhere
OCTCO/OCTF Exit Exam • Set 8 Question 11 of 30

Inert gas system has scrubber tower in a flue gas from boiler flue gas type of system. What is the arrangement for a separately fired inert gas Generator?

✓

Direct Answer

Option A: The IG Generator also has scrubber tower combined with the furnace.

In separately fired inert gas generators (IGGs), the combustion chamber/furnace and the cooling/washing scrubber tower are integrated into a compact combined vertical unit.

All Options

A
The IG Generator also has scrubber tower combined with the furnace. (Correct Answer)
B
The IG Generator can also have a separate scrubber tower.
C
The separately fired IG Generator does not have a scrubber tower.
D
Conditions (A) and (C) are suitable.

Detailed Explanation & Context

In separately fired inert gas generators (IGGs), the combustion chamber/furnace and the cooling/washing scrubber tower are integrated into a compact combined vertical unit.

Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Oil and Chemical Tanker Cargo Operations (OCTCO/OCTF).