OCTCO/OCTF Exit Exam • Set 8 Question 1 of 30
When operating with a negative suction head which of this type of pump is the best choice?
✓
Direct Answer
Option A: Reciprocating
Positive-displacement reciprocating pumps create positive suction lift and are best suited for operating with a negative suction head or high vacuum conditions.
All Options
A
Reciprocating
(Correct Answer)
B
Rotary
C
Gear
D
Centrifugal
Detailed Explanation & Context
Positive-displacement reciprocating pumps create positive suction lift and are best suited for operating with a negative suction head or high vacuum conditions.
Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Oil and Chemical Tanker Cargo Operations (OCTCO/OCTF).
Advertisement
Practice Full OCTCO/OCTF Set 8
Test yourself with 30 interactive questions, live timer, and instant score.