Type a keyword to start searching...

Use ⌘K or Ctrl+K to search from anywhere
TASCO Exit Exam • Set 6 Question 11 of 30

Identify the equipment in the IG system correctly:

✓

Direct Answer

Option D: 1- Demister; 2-O2 Analyzer; 3-Air Intake-Gas Freeing; 4- Regulating Valves; 5- Blowers

The standard IG system flow path includes the scrubber (demister), blowers, O2 analyzer, regulating valves for flow control, and air intake for gas freeing, arranged to ensure clean and safe delivery of inert gas.

All Options

A
1-O2 Analyzer; 2-Demister; 3-Air Intake-Gas Freeing; 4- Regulating Valves; 5- Blowers
B
1- Demister; 2-O2 Analyzer; 3-Regulating Valves; 4-Air Intake-Gas Freeing; 5- Blowers
C
1- Demister; 2-O2 Analyzer; 3 - Blowers; 4- Regulating Valves; 5- Air Intake-Gas Freeing
D
1- Demister; 2-O2 Analyzer; 3-Air Intake-Gas Freeing; 4- Regulating Valves; 5- Blowers (Correct Answer)

Detailed Explanation & Context

The standard IG system flow path includes the scrubber (demister), blowers, O2 analyzer, regulating valves for flow control, and air intake for gas freeing, arranged to ensure clean and safe delivery of inert gas.

Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Advanced Training for Oil Tanker Cargo Operations (TASCO).