Under SOLAS regulations, what is the minimum water capacity for the emergency fire pump on cargo vessels?
Direct Answer
Option A: At least 25 m³/h or 40% of required main pump capacity
SOLAS Chapter II-2, Regulation 10, mandates that the emergency fire pump must have a capacity of at least 25 m³/h or 40% of the total capacity of the required main fire pumps. This ensures sufficient water supply for firefighting even if the main machinery space and primary pumps are rendered inoperable.
All Options
Detailed Explanation & Context
SOLAS Chapter II-2, Regulation 10, mandates that the emergency fire pump must have a capacity of at least 25 m³/h or 40% of the total capacity of the required main fire pumps. This ensures sufficient water supply for firefighting even if the main machinery space and primary pumps are rendered inoperable.