AFF Exit Exam • Set 2 Question 4 of 30

What type of fixed fire extinguishing system is required for paint lockers having a deck area greater than 4 m²?

✓

Direct Answer

Option D: Fixed CO2 or water-sprinkling fire extinguishing system

FSS Code Chapter 7 requires paint lockers with a deck area exceeding 4 m² to be protected by a fixed fire-extinguishing system. Approved options include CO2, dry powder, or water-sprinkling systems. These systems are essential for containing high-risk flammable liquid fires in confined spaces, preventing rapid escalation to adjacent areas.

All Options

A
Inert gas generator
B
High-expansion foam only
C
Dry powder system only
D
Fixed CO2 or water-sprinkling fire extinguishing system (Correct Answer)

Detailed Explanation & Context

FSS Code Chapter 7 requires paint lockers with a deck area exceeding 4 m² to be protected by a fixed fire-extinguishing system. Approved options include CO2, dry powder, or water-sprinkling systems. These systems are essential for containing high-risk flammable liquid fires in confined spaces, preventing rapid escalation to adjacent areas.

Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Advanced Fire Fighting (AFF).

Advertisement

Practice Full AFF Set 2

Test yourself with 30 interactive questions, live timer, and instant score.

Launch Practice Simulator →

Question Discussion & Notes

0

Have a doubt, memory trick, or exam update? Share your insights with fellow mariners.

Leave a Comment / Clarification

By posting, you agree to our Terms & Moderation Policy.

Loading mariner discussions...