What safety feature prevents accidental discharge of fixed CO2 fire extinguishing systems?

✓

Direct Answer

Option B: Double-valve protection with pilot control and alarm trip switches in locked release cabinets

FSS Code, Chapter 5, mandates that fixed CO2 systems must have double-valve protection to prevent accidental discharge. This involves a primary control valve and a secondary release valve, typically housed in a locked cabinet with alarm interlocks, ensuring that the system is only activated intentionally during a confirmed emergency.

All Options

A
Automatic trigger at 30°C
B
Double-valve protection with pilot control and alarm trip switches in locked release cabinets (Correct Answer)
C
Threaded cap on main discharge pipe
D
Single push button on the bridge

Detailed Explanation & Context

FSS Code, Chapter 5, mandates that fixed CO2 systems must have double-valve protection to prevent accidental discharge. This involves a primary control valve and a secondary release valve, typically housed in a locked cabinet with alarm interlocks, ensuring that the system is only activated intentionally during a confirmed emergency.

Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Advanced Fire Fighting (AFF).

Advertisement

Practice Full AFF Set 2

Test yourself with 30 interactive questions, live timer, and instant score.

Launch Practice Simulator →

Question Discussion & Notes

0

Have a doubt, memory trick, or exam update? Share your insights with fellow mariners.

Leave a Comment / Clarification

By posting, you agree to our Terms & Moderation Policy.

Loading mariner discussions...